0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TEN 40-2410WIN

TEN 40-2410WIN

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 1 输出 3.3V 8A 9V - 36V 输入

  • 数据手册
  • 价格&库存
TEN 40-2410WIN 数据手册
DC/DC Converter TEN 40WIN Series, 40 Watt • Highest power density: 40 W in 1” x 2” x 0.4” package • • • • • Ultra wide 4:1 input range • • I/O isolation 1500 VDC • 3-year product warranty Excellent efficiency up to 90 % Output voltage adjustable Remote On/Off UL 62368-1 IEC 62368-1 Protection against short circuit and over voltage Operating temperature range –40°C to +75°C The TEN 40WIN Series is a new range of isolated high performance DC/DC-converter modules. Due to the very high efficiency of up to 90% these 40 W converters come with a footprint of only 1.0” x 2.0”. The 12 models have an ultra wide 4:1 input voltage range and a tight output voltage regulation. The output voltage is adjustable by external resistor. Remote On/Off and protection against overpower and over voltage are standard features of these converters. Typical applications are in mobile equipment, instrumentation, distributed power architectures in communication and industrial electronics and everywhere where space on the PCB is limited. Models Order Code Input Voltage Range TEN 40-2410WIN TEN 40-2411WIN TEN 40-2412WIN TEN 40-2413WIN TEN 40-2415WIN TEN 40-2422WIN TEN 40-2423WIN TEN 40-4810WIN TEN 40-4811WIN TEN 40-4812WIN TEN 40-4813WIN TEN 40-4815WIN TEN 40-4822WIN TEN 40-4823WIN 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 8'000 mA 8'000 mA 3'330 mA 2'670 mA 1'670 mA 1'670 mA 1'330 mA 8'000 mA 8'000 mA 3'330 mA 2'670 mA 1'670 mA 1'670 mA 1'330 mA Vnom Efficiency Imax –12 VDC –15 VDC 1'670 mA 1'330 mA –12 VDC –15 VDC 1'670 mA 1'330 mA typ. 89 % 90 % 89 % 89 % 91 % 88 % 88 % 89 % 90 % 90 % 90 % 91 % 88 % 88 % Options TEN-HS4 - Optional Heat Sink: www.tracopower.com/products/ten-hs4.pdf TEN-HS6 - Optional Heat Sink: www.tracopower.com/products/ten-hs6.pdf www.tracopower.com September 20, 2023 Page 1 / 5 TEN 40WIN Series, 40 Watt Input Specifications Input Current 24 Vin models: 90 mA typ. (3.3 Vout model) 90 mA typ. (5 Vout model) 95 mA typ. (12 Vout model) 105 mA typ. (15 Vout model) 115 mA typ. (24 Vout model) 65 mA typ. (12 / -12 Vout model) 65 mA typ. (15 / -15 Vout model) 48 Vin models: 55 mA typ. (3.3 Vout model) 55 mA typ. (5 Vout model) 60 mA typ. (12 Vout model) 65 mA typ. (15 Vout model) 75 mA typ. (24 Vout model) 45 mA typ. (12 / -12 Vout model) 45 mA typ. (15 / -15 Vout model) 24 Vin models: 1'240 mA max. (3.3 Vout model) 1'850 mA max. (5 Vout model) 1'870 mA max. (12 Vout model) 1'870 mA max. (15 Vout model) 1'835 mA max. (24 Vout model) 1'890 mA max. (12 / -12 Vout model) 1'890 mA max. (15 / -15 Vout model) 48 Vin models: 620 mA max. (3.3 Vout model) 930 mA max. (5 Vout model) 930 mA max. (12 Vout model) 930 mA max. (15 Vout model) 920 mA max. (24 Vout model) 950 mA max. (12 / -12 Vout model) 950 mA max. (15 / -15 Vout model) 24 Vin models: 50 VDC max. (100 ms max.) 48 Vin models: 100 VDC max. (100 ms max.) 24 Vin models: 8.3 VDC typ. 48 Vin models: 16.5 VDC typ. 24 Vin models: 30 mAp-p typ. 48 Vin models: 20 mAp-p typ. 24 Vin models: 8'000 mA (slow blow) 48 Vin models: 4'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal LC-Type - At no load - At full load Surge Voltage Under Voltage Lockout Reflected Ripple Current Recommended Input Fuse Input Filter Output Specifications Output Voltage Adjustment See application note: Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) - Voltage Balance (symmetrical load) single output models: dual output models: single output models: dual output models: dual output models: –10% to +20% (24 Vout models) ±10% (other models) (single output models only) (By external trim resistor) www.tracopower.com/overview/ten40win Output power must not exceed rated power! ±1% max. 0.5% max. 0.5% max. 0.5% max. 1% max. (Output 1) 1% max. (Output 2) 2% max. All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 2 / 5 TEN 40WIN Series, 40 Watt Ripple and Noise (20 MHz Bandwidth) - single output 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: - dual output Capacitive Load - single output - dual output Minimum Load - single output - dual output Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Transient Response - Response Deviation - Response Time 100 mVp-p max. (w/ 1µF MC || 10µF TC) 100 mVp-p max. (w/ 1µF MC || 10µF TC) 150 mVp-p max. (w/ 1µF MC || 10µF TC) 150 mVp-p max. (w/ 1µF MC || 10µF TC) 150 mVp-p max. (w/ 1µF MC || 10µF TC) 150 / 150 mVp-p max. (w/ 1µF MC || 10µF TC) 150 / 150 mVp-p max. (w/ 1µF MC || 10µF TC) 21'000 µF max. 13'600 µF max. 2'400 µF max. 1'500 µF max. 600 µF max. 1'200 / 1'200 µF max. 750 / 750 µF max. 0 % of Iout max. 0 % of Iout max. 0 % of Iout max. 0 % of Iout max. 0 % of Iout max. 9 % of Iout max. 8 % of Iout max. ±0.02 %/K max. 30 ms max. Continuous, Automatic recovery 150% typ. of Iout max. 3% typ. / 5% max. (75% to 100% Load Step) 250 µs typ. (75% to 100% Load Step) Safety Specifications Safety Standards CSA-C22.2, No. 60950-1 EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/ten40win PD 3 Not mains connected - IT / Multimedia Equipment - Certification Documents Pollution Degree Over Voltage Category EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions External filter proposal: EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge - Conducted RF Disturbances - PF Magnetic Field Continuous: EN 55032 class A (with external filter) FCC Part 15 class A (with external filter) EN 55032 class A (with external filter) FCC Part 15 class A (with external filter) www.tracopower.com/overview/ten40win EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 3 A/m, perf. criteria A All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 3 / 5 TEN 40WIN Series, 40 Watt General Specifications Relative Humidity Temperature Ranges Power Derating Over Temperature Protection Switch Off Cooling System Remote Control 95% max. (non condensing) –40°C to +75°C +105°C max. –50°C to +125°C Depending on model See application note: www.tracopower.com/overview/ten40win 110°C typ. - Operating Temperature - Case Temperature - Storage Temperature - High Temperature - Protection Mode - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability Washing Process - Input to Output, 60 s - Input to Output, 1 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Thermal Impedance Natural convection (20 LFM) On: 3.5 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 2.5 mA max. -0.5 to 0.5 mA 6'000 m max. 285 kHz typ. (PWM) (24 Vout models) 320 kHz typ. (PWM) (other models) Functional Insulation 1'500 VDC 1'800 VDC 1'000 MΩ min. 1'500 pF typ. 330'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf Alu alloy, black anodized coating Non-conductive FR4 (UL 94 V-0 rated) Epoxy (UL 94 V-0 rated) Copper Alloy (C6801) Nickel (2.5 µm min.) Gold (75 - 125 nm), glossy Metal Case PCB Mount THD (Through-Hole Device) 2" x 1" Lead-Free Wave Soldering 260°C / 10 s max. 30 g 12 K/W typ. 10 K/W typ. (with Heat Sink) www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) 14ea9ef9-80c5-4478-895c-1762f23c29c8 - Case to Ambient Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/ten40win All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 4 / 5 TEN 40WIN Series, 40 Watt 3 Pinout 25.4 (1.00) 2.54 5 3.6 (0.14) 1.85 (0.073) (0.400) Bottom view 10.16 (0.400) 10.16 2 (0.400) 4 1 10.16 5.08 (0.200) 50.8 (2.00) (0.100) Outline Dimensions 6 Single Dual 1 +Vin (Vcc) +Vin (Vcc) 2 –Vin (GND) –Vin (GND) 3 Remote On/Off Remote On/Off 4 +Vout +Vout 5 –Vout Common 6 Trim –Vout 5.5 (0.22) h 45.72 (1.800) Pin Ø1.0 (Ø0.04) h=11.0 (0.43) for 24 VDC output models h=10.2 (0.40) for other models Dimensions in mm (inch) Tolerances: x.x ±0.25 (x.xx ±0.01) x.xx ±0.13 (x.xxx ±0.005) Pin diameter tolerances: x.x ±0.05 (x.xx ±0.002) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 20, 2023 Page 5 / 5
TEN 40-2410WIN 价格&库存

很抱歉,暂时无法提供与“TEN 40-2410WIN”相匹配的价格&库存,您可以联系我们找货

免费人工找货